AC Input
85-265VAC continuous, 47-63Hz
US power cord standard
Efficiency 69-84% dependant on model
Power factor - 0.99
Softstart AC inrush
Output Characteristics
Load Regulation:
CV 0.005% +2mV
CC 0.01% +5mA
Line Regulation: (85-132, 170-265VAC)
CV 0.005% +1mV
CC 0.01% +2mA
Ripple: CV (5Hz to 1MHz BW), 5mV RMS (20MHz BW), 50mV p-p
Stability: better than 0.05%
Operating temp.: 0-50 Deg C full output. Series parallel operation
Remote sense up to 0.5V per line
Protective Features
Adjustable Overvoltage, Undervoltage
Overtemperature
Foldback (overcurrent)
Safe or automatic restart mode |
Agency Approvals
CE Mark standard
Safety: UL3111-1, EN61010-1
EMC: EN61326-1, IEC61326-1, FCC Part 15 (Class A)
EN55022B Conducted
EN55022A Radiated
|