AC Input
0.6 to 1.8 kW: 115 VAC (Standard),
220 VAC (optional) single phase
2.8 kW, and 10 kW: 208 VAC (standard), 440 VAC (optional) three
phase
Consult factory for additional inputs
Output Characteristics
Regulation: 0.1%
Stability: 0.05%
Transient response: 30% load change will recover to 2% within 75
milliseconds.
Operating temperature: 0-40 deg C, derate above 40 deg C |
Protective Features
Overvoltage (optional)
Overtemperature
OverCurrent
Programming
Front panel controls and remote analog
resistance, voltage and current programming (standard);
0-5V and 0-10V optional)
RS232 and IEEE-488 (optional)
Mechanical
600 W and 1 kW models: 3 1/2" H,
18 1/2" D, 60-65 lbs. (27-29 kg)
1.8 kW: 5 1/2" H, 18 1/2" D, 95 lbs. (43 kg)
2.5 and 2.8 kW: 7" H, 18 1/2" D, 125-180 lbs. (57-82 kg)
5 kW: 8 3/4" H, 22" D, 240 lbs. (109 kg)
10 kW 12 1/4" H, 22" D, 350 lbs. (159 kg)
|