Remote Control Interface Descriptions

500A, 102A, 152A and 202A
This series of power supply feature a 15pin D-type remote interface located on the AC input panel of the supply. The table below shows details of the function and the pin-out for the connector.

PIN

SIGNAL NAME

I/O

DESCRIPTION

1

ENABLE/RESET

INPUT

A high signal (+10 to 15V) with respect to ground (pin 14) will enable the power supply. Latching faults can be cleared by cycling this switch. Ground or open disables the supply.

5

V PROGRAM

INPUT

A 0-10V signal with respect to ground at this pin programs the output voltage proportionally from zero to rated output.

7

VPEAK

OUTPUT

A 0-10V signal (with respect to ground) proportional to the peak of the output charging voltage. Can be used to drive a meter displaying peak output voltage.

8

VANALOG

OUTPUT

0-10V analog of output charging voltage waveform (+/- 1%).

10

INHIBIT

INPUT

A +10 to 15V with respect to ground, disables the unit. Open or ground allows operation. This input can be used to disable charging during HV switch recovery.

9, 11

+15V

OUTPUT

15V regulated. Can be used for user programming applications 20mA max.

14

GND

OUTPUT

Control circuit return. Also chassis/earth ground

15

INHIBIT LED

OUTPUT

Open collector. Indicates that the power supply is receiving an INHIBIT signal.

13

EOC LED

OUTPUT

Open collector. Indicates that the power supply is reaching end-of-charge, i.e. the V PROGRAM set point.

3, 6

SUMMARY FAULT LED

OUTPUT

Open collector. Indicates an output overvoltage. Temperature fault or low input voltage condition.

2

LOAD FAULT LED

OUTPUT

Indicates a shorted O/P or a very large load capacitor.


402, 802 and XR802
These power supplies feature a common interface via a 25pin D-type connector located on the rear panel of the unit. The table below shows details of the function and the pin-out for the connector.

PIN SIGNAL NAME I/O DESCRIPTION
1 VANALOG OUTPUT 0-10V analog of output charging voltage waveform (+/- 1%).
3 INHIBIT LED OUTPUT Open collector output. Indicates the PS is receiving an inhibit input
5 EOC LED OUTPUT Open collector output. Indicates the PS has reached end of charge
7 INHIBIT INPUT 5 to 15V inhibits unit operation, Open or Gnd allows operation. Use this signal to disable charging during HV switch recovery
8 ENABLE/RESET INPUT 15V = High Voltage On, Gnd or open = High Voltage Off
9 VPEAK OUTPUT 0-10V Peak detector of output waveform
10 HV ON LED OUTPUT Open collector output. Indicates the HV is ON
12 GND   Control circuit return. Also chassis ground
13 IANALOG OUTPUT Analog of output waveform (+/-1%)
14 +15V OUTPUT 15V through 100ohm series resistor
16 OVERTEMP LED OUTPUT Open collector output. Indicates Overtemp fault
17 INTERLOCK LED OUTPUT Open collector output. Indicates the interlock is open
18 LOAD FAULT LED OUTPUT Open collector output. Indicates output overload, over-voltage, or open circuit condition
19 SUMMARY FAULT LED OUTPUT Open collector output. Indicates summary fault
20 INHIBIT INPUT 0V inhibits unit, 15V or open allows operation
22 V PROGRAM INPUT 0-10V signal = 0 to 100% of rated voltage
23 HV OFF LED OUTPUT Open collector output. Indicates the HV is OFF
24 GND   Control circuit return. Also chassis ground
25 +12V LED OUTPUT 12V at 100mA max for powering status LEDs


LC1202
This power supply features an interface similar to the 402/802/XR802 with some additional signals, via a 25pin D-type connector located on the rear panel of the unit. The table below shows details of the function and the pin-out for the connector.

PIN SIGNAL NAME I/O DESCRIPTION
1 VANALOG OUTPUT 0-10V analog of output charging voltage waveform (+/- 1%).
3 INHIBIT LED OUTPUT Open collector output. Indicates the PS is receiving an inhibit input
5 EOC LED OUTPUT Open collector output. Indicates the PS has reached end of charge
7 INHIBIT INPUT 5 to 15V inhibits unit operation, Open or Gnd allows operation. Use this signal to disable charging during HV switch recovery
8 ENABLE/RESET INPUT 15V = High Voltage On, Gnd or open = High Voltage Off
9 VPEAK OUTPUT 0-10V Peak detector of output waveform
10 HV ON LED OUTPUT Open collector output. Indicates the HV is ON
12 GND   Control circuit return. Also chassis ground
13 IANALOG OUTPUT Analog of output waveform (+/-1%)
14 +15V OUTPUT 15V through 100ohm series resistor
15 TEMP OUTPUT 0-10V signal indicating the temperature of the main inverter heatsink. 0V=10C 10V=60C
16 OVERTEMP LED OUTPUT Open collector output. Indicates Overtemp fault
17 INTERLOCK LED OUTPUT Open collector output. Indicates the interlock is open
18 LOAD FAULT LED OUTPUT Open collector output. Indicates output overload, over-voltage, or open circuit condition
19 SUMMARY FAULT LED OUTPUT Open collector output. Indicates summary fault
20 INHIBIT INPUT 0V inhibits unit, 15V or open allows operation
21 PHASE LOSS LED OUTPUT Open collector output. Indicates loss of one or more AC input phases
22 V PROGRAM INPUT 0-10V signal = 0 to 100% of rated voltage
23 HV OFF LED OUTPUT Open collector output. Indicates the HV is OFF
25 GND   Control circuit return. Also chassis ground


203 and 303
These power supplies feature a common interface via a 25pin D-type connector located on the rear panel of the unit. The table below shows details of the function and the pin-out for the connector.

PIN SIGNAL NAME I/O DESCRIPTION
1 +15V OUTPUT 15V at 125mA max 
2 SUMMARY FAULT LED OUTPUT Open collector output. Indicates a fault condition
3 INHIBIT LED OUTPUT Open collector output. Indicates the PS is receiving an inhibit input
4 EOC LED OUTPUT Open collector output. Indicates the PS has reached end of charge
5 EXCESS REVERSAL LED OUTPUT Open collector. Senses excess reversal in output circuit.
6 COOLANT WARNING LED OUTPUT Open collector. Active is the coolant level is low
7 OVER VOLTAGE LED OUTPUT Open collector. Senses excess voltage at the output.
8 ARC LED OUTPUT Open collector. Senses arcing in the HV tank.
9 AUTO DWELL INPUT 0-10V for autoinhibit control.
Range 1, 0-10V = 0.5 to 5ms
Range 2, 0-10V = 5 to 50ms
10 ENABLE/RESET INPUT 15V = High Voltage On, Gnd or open = High Voltage Off
11 V PROGRAM INPUT 0-10V signal = 0 to 100% of rated voltage
12 CURRENT METER OUTPUT +10V DC indicates max current
13 VANALOG OUTPUT 0-10V analog of output charging voltage waveform (+/- 1%).
14 INTERLOCK LED OUTPUT Open collector output. Indicates the interlock is open
15 INPUT POWER FAULT LED OUTPUT Open collector output. Indicates that an input power fault has been detected.
16 AUTO DWELL LED OUTPUT Open collector output. Indicates auto-dwell is activated
17 LOAD FAULT LED OUTPUT Open collector output. Indicates output overload.
18 N/C
19 COOLANT FAULT LED OUTPUT Open collector output. Indicates internal coolant over temperature or low coolant level
20 PURGE PUMP LED OUTPUT Open collector output. Indicates the internal purge pump is operating
21 DIGITAL GND Common ground for digital circuits
22 INHIBIT INPUT >3V inhibits unit, 0V allows operation
23 ANALOG GND Use for reference of any analog inputs or outputs
24 +11V DC OUTPUT Regulated +11V output for references
25 VOLT METER OUTPUT +10V DC indicates max voltage
 