Average Charging Rate
12,000 J/s at rated Output Voltage.
Peak Charging Rate
13,500 J/s at rated Output Voltage.
Average Continuous DC Power
15,000 Watts
(derated to 12,000W with 208VAC input)
Standard Voltage Ranges
1, 2, 4, 5,
10, 15, 20, 30 kV.
All models continuously variable from 0 to 100% of rated voltage output.
Linear to within 1% of full scale.
Accuracy 1% of rated.
High Voltage Assembly
Sealed silicone oil Insulated HV section with zero air.
Polarity
Available as fixed Positive or Negative, Please Specify.
Output Connector/Cable
| Output
Voltage |
Connector |
Cable |
| 1-30kV |
Proprietary |
DS 2214SSJ |
AC Input
208 VAC 3 ph (180-264VAC) 50/60 Hz, 50A
400 VAC 3 ph (340-460VAC) 50/60 Hz, 26A
480 VAC 3 ph (432-528VAC)
50/60 Hz, 20A
Field selectable with appropriate conversion kit 208/400 (VAC versions only).
(Please specify at the time of order).
|
Input Connector
VDE, UL, CSA, approved.
AC Line Contactor
VDE, UL, CSA, approved line contactor (Standard on LC1202L. LC1202S, option on LC1202OEM).
Power Factor
Passive PFC 0.9 min
Efficiency
Better than 90%
Stored Energy
Less than 0.3 Joules all models.
Stability
0.2% per hour after 1 hour warm-up.
Cooling
Flowed water at 2US GPM (7.6L/min) max. inlet temperature 35 oC. All water paths are at ground potential and are copper, brass or hydraulic hose. Connections via 12mm pipe to standard Swagelok type fittings on back of unit.
Pulse to Pulse Repeatability
+/- 0.1% to 300Hz standard
+/- 0.1% to 1kHz option
Temperature Coefficient
100 PPM per °C
Ambient Temperature
Storage: -40 to +80 °C
Operating: 5 to +45 °C
|
Humidity
10-90% Non-condensing
Protection
The power supply is protected against open circuits, short circuits, overloads and arcs.
Agency Approvals
Certification to EN60950 (pending) Mechanical
19"(482mm) x 17"(432mm) x 8.72"(222mm)
Weight - 100lbs, 46kg
Click here for sketch (PDF)
Accessories
Detachable 10 foot HV cable
Operating manual
Remote Control
Via 25pin d-type connector on rear panel. Click
here for details
Options
| Suffix-5V |
0 to
+5 volt program (0 to full-scale output) |
| Suffix-LP |
Latching
overload protection |
| Suffix-EN |
Low Enable (0V=Enable) |
| Suffix-RS |
Remote
sense |
| Suffix-CT |
Optional
internal contactor for OEM only (standard on L/S
models) |
|