AC Input
208 VAC or 400 VAC, 3 phase, 50/60 Hz. (Please specify at the time of order).
Average Charging Rate
8000 J/s at rated Output Voltage.
Peak Charging Rate
9000 J/s at rated Output Voltage.
Standard Voltage Ranges
1, 1.5, 2, 3, 4, 5,
10, 15, 20, 30, 40, 50 kV.
All models continuously variable from 0 to 100% of rated voltage output.
Linear to within 1% of full scale.
Accuracy 1% of rated.
Polarity
Available as fixed Positive or Negative, Please Specify.
High Voltage Assembly
Oil Insulated HV section
(Air available on limited models - call factory)
Output Connector/Cable
| Output
Voltage |
Connector |
Cable |
| 1-39kV |
Proprietary |
DS
2124 |
| 40-50kV |
Proprietary |
DS
2214 |
1-6kV
(Air Option) |
Amphenol
HN |
RG-8/U |
|
Input Connector
VDE, UL, CSA, approved.
Power Factor
Passive PFC 0.85 min
Efficiency
Better than 85%
Stored Energy
Less than 0.3 Joules all models.
Stability
0.2% per hour after 1 hour warm-up.
Pulse to Pulse Repeatability
+/- 0.2% to 1kHz. For higher repetition rates, consult factory
Temperature Coefficient
100 PPM per °C
Ambient Temperature
Storage: -40 to +80 °C
Operating:-0 to +45 °C
Humidity
10-90% Non-condensing
Protection
The power supply is protected against open circuits, short circuits, overloads and arcs.
Agency Approvals
Certification to EN60950 (pending) |
Mechanical
19"(482mm) x 17"(432mm) x 7"(178mm)
Weight - 80lbs, 37kg
Accessories
Detachable 10 foot HV cable
Operating manual
Remote Control
Via 25pin d-type connector on rear panel. Click
here for details
Options
| Suffix-5V |
0 to
+5 volt program (0 to full-scale output) |
| Suffix-LP |
Latching
overload protection |
| Suffix-EN |
Low Enable (0V=Enable) |
| Suffix-CT |
Optional
internal contactor for OEM only (standard on L/S
models) |
|